Electricity is the backbone of the model 1. Every region has an electricity bus at transmission level, and in the sector-coupled model most other carriers are produced from or converted into electricity.

Demand

Hourly electricity demand per country is taken from historical load statistics of the transmission system operators and the Open Power System Data platform 2, filled and cleaned where the records have gaps, and optionally supplemented with synthetic time series for years or countries without records.

Within a country, demand is distributed to regions with a spatial key. For households and services the key combines population and economic activity; where available, gridded estimates of annual electricity consumption refine the picture. Industrial electricity demand is placed at the sites of energy-intensive industry instead, see Industry.

Two parts are subtracted from the historical load and modelled separately: the electricity used today for heating, so that power-to-heat can be optimised on its own, and the electricity used in industry, so that further electrification of industry can be represented. Cooling demand stays in the electricity demand and is not changed.

The historical load is used as it is, distributed with the same spatial key. Nothing is subtracted for heating or industry.

Supply

Renewables

Wind and solar capacities are decided by the optimisation within limits set by land availability and the weather.

Potentials. For each technology and region, the eligible land is determined from land cover 3, nature protection areas 4, bathymetry 5 and shipping lanes, together with distance criteria such as a minimum distance from shore for offshore wind. The eligible area is multiplied with an allowed deployment density to obtain the installable capacity 67. The cost of connecting new capacity to the grid follows from the average distance of the eligible sites to the substation, and for offshore wind from the distance to the landfall. Offshore wind is split into near-shore sites with AC connection, far-shore sites with DC connection and deep-water sites for floating turbines. Rooftop solar potential is derived from population density 8. Each region can further be split into resource classes so that sites of different quality within one region are represented separately.

Time series. Hourly capacity factors are computed from the ERA5 reanalysis 9 and the SARAH satellite irradiation record 10 with atlite 11: wind speeds through turbine power curves, solar irradiation through panel models with fixed or single-axis tracking mounts, and hydro inflow from surface runoff scaled to historical generation statistics. The grid-cell time series are aggregated to regions in proportion to the mean capacity factor of each cell, which assumes that new capacity is built where the resource is best.

Hydropower. Run-of-river, reservoir and pumped-hydro plants are taken from the power plant database with their existing capacities and are not expandable. Reservoir inflow follows the runoff-based time series.

Geothermal. Enhanced geothermal systems can generate electricity, and heat for district heating, where the geological potential allows. Their potential and cost per region come from a gridded assessment.

Conventional plants

Existing thermal power plants come from the open powerplantmatching database 12, which merges several public sources into one list with location, fuel, technology, capacity and commissioning year. Existing wind and solar capacities are taken from the plant-level records in the same database, or optionally from national statistics, and placed within a country in proportion to resource quality and potential.

New gas turbines in open and combined cycle can be built. By default only gas turbines may be built new among the thermal plants; nuclear, coal, lignite and oil plants enter transition pathways as existing capacities.

Thermal plants are links from a fuel bus, so that their fuel can be fossil, biogenic or synthetic, see Methane. Further options to generate electricity from other carriers are hydrogen turbines and fuel cells, combined heat and power plants, methanol-fired plants and oxy-fuel gas plants with inherent carbon capture.

There are no fuel buses. Conventional plants are generators with a fuel price and a carbon intensity per carrier, and the set of carriers that may be built new is chosen in the configuration. Optional operational detail for these plants, such as an operating reserve margin and linearised unit commitment, is only available here.

Conversion

Electricity is the input to most other carriers: heat pumps and resistive heaters make heat, electrolysers make hydrogen, and electric vehicles, electrified industrial processes and direct air capture draw power. These links are described on the pages of the carriers they produce. The flexibility they add, by shifting their consumption to hours of abundant wind and solar, is one of the main effects of sector coupling on the electricity system 13.

Storage

Electricity can be stored in stationary batteries and in the existing pumped-hydro plants. Batteries are represented with separate energy and power components, so that duration and capacity are sized independently, with distinct costs for utility-scale and home batteries. Several battery chemistries and other electricity storage technologies with different typical durations, from hours to days, can be offered to the optimisation.

Electric vehicle batteries add a large flexible storage, see Transport, and hydrogen with its underground storage acts as seasonal storage when it is re-electrified, see Hydrogen.

Batteries and hydrogen storage are storage units with a fixed energy-to-power ratio per technology, or optionally stores with separate charging and discharging links. There is no hydrogen carrier beyond this storage.

Transport

Transmission grid

The transmission grid is derived from OpenStreetMap 14. Substations, lines, cables and HVDC links at and above the highest voltage levels are extracted, their tags cleaned and standardised, and substations close to each other merged into one bus. Missing circuit counts are filled by heuristics, and each line is assigned a standard line type of its voltage level 15, from which impedance and thermal rating follow. HVDC links keep their reported ratings and are connected to the nearest AC bus through converter links. The dataset has been validated against the transmission system operators' inventory statistics. An alternative base network can be built from the ENTSO-E reference grid 16.

Power flow on the AC network follows linearised power flow equations, so that Kirchhoff's voltage law is respected 17; HVDC links are transport links. A security margin reduces the usable line capacity to approximate N-1 safe operation, and dynamic line rating from weather data can be enabled.

Grid expansion is endogenous. Existing corridors can be reinforced, and the total expansion can be capped relative to today's grid volume or cost. Resistive losses on AC lines are approximated piecewise linearly, and losses on HVDC links per distance.

Distribution grid

The grid below transmission level is not represented topologically. Instead, each region has a low-voltage bus connected to the transmission bus by a link whose capacity is optimised. Electricity demand, rooftop solar, heat pumps, resistive heaters, home batteries and electric vehicle chargers connect to the low-voltage side; large generators and storage connect to the transmission side. Distribution capacity is then expanded only where local generation and demand do not balance, and distribution losses are represented as a fixed share.

There is no distribution level; all technologies connect to the transmission bus.

Further reading


  1. Jonas Hörsch, Fabian Hofmann, David Schlachtberger, and Tom Brown. Pypsa-eur: an open optimisation model of the European transmission system. Energy Strategy Reviews, 22:207–215, 2018. arXiv:1806.01613, doi:10.1016/j.esr.2018.08.012. ↩

  2. Jonathan Muehlenpfordt. Open Power System Data - Time series. October 2020. doi:10.25832/TIME_SERIES/2020-10-06. ↩

  3. European Environment Agency (EEA). Corine Land Cover (CLC) 2012. 2022. URL: https://land.copernicus.eu/pan-european/corine-land-cover/clc-2012. ↩

  4. European Environment Agency (EEA). Natura 2000 data - the European network of protected sites. 2022. URL: https://www.eea.europa.eu/data-and-maps/data/natura-13. ↩

  5. GEBCO. GEBCO 2014 Grid. 2022. URL: https://www.gebco.net/data\_and\_products/historical\_data\_sets/\#gebco\_2014. ↩

  6. Russell McKenna, Stefan Pfenninger, Heidi Heinrichs, Johannes Schmidt, Iain Staffell, Christian Bauer, Katharina Gruber, Andrea N. Hahmann, Malte Jansen, Michael Klingler, Natascha Landwehr, Xiaoli Guo Larsén, Johan Lilliestam, Bryn Pickering, Martin Robinius, Tim Tröndle, Olga Turkovska, Sebastian Wehrle, Jann Michael Weinand, and Jan Wohland. High-resolution large-scale onshore wind energy assessments: a review of potential definitions, methodologies and future research needs. Renew. Energ., 182:659–684, January 2022. doi:10.1016/j.renene.2021.10.027. ↩

  7. Jonathan Bosch, Iain Staffell, and Adam D. Hawkes. Temporally explicit and spatially resolved global offshore wind energy potentials. Energy, 163:766–781, November 2018. doi:10.1016/j.energy.2018.08.153. ↩

  8. Katalin Bódis, Ioannis Kougias, Arnulf Jäger-Waldau, Nigel Taylor, and Sándor Szabó. A high-resolution geospatial assessment of the rooftop solar photovoltaic potential in the European Union. Renew. Sust. Energ. Rev., 114:109309, October 2019. doi:10.1016/j.rser.2019.109309. ↩

  9. Hans Hersbach, Bill Bell, Paul Berrisford, Shoji Hirahara, András Horányi, Joaquín Muñoz-Sabater, Julien Nicolas, Carole Peubey, Raluca Radu, Dinand Schepers, Adrian Simmons, Cornel Soci, Saleh Abdalla, Xavier Abellan, Gianpaolo Balsamo, Peter Bechtold, Gionata Biavati, Jean Bidlot, Massimo Bonavita, Giovanna De Chiara, Per Dahlgren, Dick Dee, Michail Diamantakis, Rossana Dragani, Johannes Flemming, Richard Forbes, Manuel Fuentes, Alan Geer, Leo Haimberger, Sean Healy, Robin J. Hogan, Elías Hólm, Marta Janisková, Sarah Keeley, Patrick Laloyaux, Philippe Lopez, Cristina Lupu, Gabor Radnoti, Patricia de Rosnay, Iryna Rozum, Freja Vamborg, Sebastien Villaume, and Jean-Noël Thépaut. The ERA5 global reanalysis. Q. J. R. Meteorol. Soc., 146(730):1999–2049, 2020. doi:10.1002/qj.3803. ↩

  10. Uwe Pfeifroth, Steffen Kothe, Richard Müller, Jörg Trentmann, Rainer Hollmann, Petra Fuchs, and Martin Werscheck. Surface radiation data set - heliosat (SARAH) - edition 2. 2017. doi:10.5676/EUM_SAF_CM/SARAH/V002. ↩

  11. Fabian Hofmann, Johannes Hampp, Fabian Neumann, Tom Brown, and Jonas Hörsch. Atlite: a lightweight Python package for calculating renewable power potentials and time series. JOSS, 6(62):3294, June 2021. doi:10.21105/joss.03294. ↩

  12. Fabian Gotzens, Heidi Heinrichs, Jonas Hörsch, and Fabian Hofmann. Performing energy modelling exercises in a transparent way - the issue of data quality in power plant databases. Energy Strategy Rev., 23:1–12, January 2019. doi:10.1016/j.esr.2018.11.004. ↩

  13. T. Brown, D. Schlachtberger, A. Kies, S. Schramm, and M. Greiner. Synergies of sector coupling and transmission reinforcement in a cost-optimised, highly renewable European energy system. Energy, 160:720–739, 2018. doi:10.1016/j.energy.2018.06.222. ↩

  14. Bobby Xiong, Davide Fioriti, Fabian Neumann, Iegor Riepin, and Tom Brown. Modelling the high-voltage grid using open data for Europe and beyond. Scientific Data, 2025. doi:10.1038/s41597-025-04550-7. ↩

  15. Dietrich Oeding and Bernd Rüdiger Oswald. Elektrische Kraftwerke und Netze. Springer, 2011. ISBN 978-3-642-19245-6 978-3-642-19246-3. doi:10.1007/978-3-642-19246-3. ↩

  16. ENTSO-E. TYNDP: Ten-Year Network Development Plan. 2018. URL: https://tyndp.entsoe.eu/tyndp2018/. ↩

  17. Jonas Hörsch, Henrik Ronellenfitsch, Dirk Witthaut, and Tom Brown. Linear optimal power flow using cycle flows. Electr. Power Syst. Res., 158:126–135, 2018. doi:10.1016/j.epsr.2017.12.034. ↩