Heating

Electricity-onlySector-coupledOvernightMyopicPerfect foresight

Building heat is the largest energy demand in Europe after transport and has a strong seasonal profile 1. The model resolves space and water heating of the residential and services sectors per region and distinguishes buildings that are served by district heating from those with individual heating systems.

Demand

Annual totals. Annual heat demand per country is taken from energy balances 23 as useful energy, that is the heat delivered rather than the fuel burned, and split into space heating and hot water, and into residential and services buildings.

Time series. Space heat demand is spread over the year in proportion to daily heating degree days computed from ambient temperature, so that cold days carry more demand. Within the day, standard load profiles 4 distribute the demand over the hours, with different shapes for weekdays and weekends and for residential and services buildings. Hot water demand is constant over the year.

Heat systems. Within a country, heat demand is split between urban and rural areas using population density, and each part is distributed to regions in proportion to its population. Dense urban areas can be served by district heating. This results in five heat systems per region, each with its own supply options:

Heat system Buildings served
Urban central District heating in dense urban areas, residential and services
Residential urban decentral Residential buildings in urban areas without district heating
Services urban decentral Services buildings in urban areas without district heating
Residential rural Residential buildings in areas with low population density
Services rural Services buildings in areas with low population density, including agriculture

Three heat buses by default

The residential and services buses of the same type are merged by default to keep the problem small, leaving one district heating, one urban decentral and one rural bus per region.

The share of urban demand on district heating is exogenous and can grow along the planning years up to a potential. District heating networks incur lump-sum distribution losses. Spatial data on district heating areas is used to estimate where heat sources and large storage can be connected.

Renovation. Renovation of the thermal envelope reduces space heat demand. It can be prescribed as an exogenous reduction, or it can be optimised per region and heat system 1. In the endogenous case, costs per unit of energy saved are estimated from the building stock and renovation costs, and several insulation depths are offered to the optimisation as a step-wise supply curve, so that it can trade insulation against supply capacity.

Supply

Decentral heating

Individual buildings can be heated with air-sourced heat pumps, ground-sourced heat pumps in rural areas, resistive heaters, gas, oil and biomass boilers, micro combined heat and power units, and solar thermal collectors. The coefficient of performance of heat pumps follows the temperature difference between the source and the sink 5; it is lower on cold days and more stable for ground-sourced units, whose source temperature varies less. Solar thermal yield follows irradiation and collector orientation.

District heating

District heating networks have more options because they can host large plants. Combined heat and power plants, fired with solid biomass or methane by default and optionally with other fuels or with non-recyclable waste, run with or without carbon capture in back-pressure mode with a fixed ratio of electricity to heat. Large heat pumps, resistive heaters, boilers, fuel cells and enhanced geothermal systems complete the picture.

Large heat pumps can draw on several sources. Besides ambient air, which is the default, the model can exploit geothermal heat, rivers and the sea, each limited by a regional potential derived from geological and hydrological data within reach of the district heating areas. Their coefficient of performance is approximated from the source temperature and the network supply temperature with a thermodynamic model. The supply temperature itself is approximated from ambient temperature following measured reference curves 6: it is highest on cold days and lowest on mild days, and it can decline over the planning years as networks modernise. Sources that are hot enough can feed the network directly without a heat pump.

Waste heat from conversion processes is a further source: electrolysis, fuel cells, Fischer-Tropsch synthesis, methanolisation and ammonia synthesis reject heat that can be fed into district heating where these plants are located.

In transition pathways the existing heating stock matters. Installed capacities of boilers, heat pumps and resistive heaters are taken from a European survey, assigned a lifetime and decommissioned gradually, so that the model replaces them over time, see Foresight.

Storage

Water tanks provide short-term storage for individual buildings, and large pit storages provide seasonal storage for district heating. Both are modelled as stores with standing losses; pit storage capacity can follow the network temperatures 7, and supplemental heating covers the times when the stored water is not hot enough. Aquifer storage is available where suitable aquifers underlie district heating areas 8. Water tanks are switched on by ttes, pit storage by district_heating: ptes: enable and aquifer storage by district_heating: ates: enable.

Building thermal mass can optionally be used for demand-side management of residential space heating: supply may run ahead of demand within a day, as long as the buffer is empty again at fixed hours, so that buildings cannot act as seasonal storage. Surplus heat, for example from waste heat in summer, can be vented so that heat supply never has to be curtailed.

Further reading


  1. Elisabeth Zeyen, Veit Hagenmeyer, and Tom Brown. Mitigating heat demand peaks in buildings in a highly renewable European energy system. Energy, 231:120784, 2021. URL: http://arxiv.org/abs/2012.01831, doi:10.1016/j.energy.2021.120784. ↩↩

  2. European Commission. Joint Research Centre. JRC-IDEES: Integrated Database of the European Energy Sector: methodological note. Technical Report, Publications Office, LU, 2017. URL: https://data.europa.eu/doi/10.2760/182725. ↩

  3. eurostat. Energy balances. 2021. URL: https://ec.europa.eu/eurostat/web/energy/data/energy-balances. ↩

  4. BDEW. BDEW heat demand profiles. 2021. URL: https://github.com/oemof/demandlib. ↩

  5. Iain Staffell, Dan Brett, Nigel Brandon, and Adam Hawkes. A review of domestic heat pumps. Energy Environ. Sci., 5(11):9291, 2012. doi:10.1039/c2ee22653g. ↩

  6. Henrik Pieper, Torben Ommen, Brian Elmegaard, and Wiebke Brix Markussen. Assessment of a combination of three heat sources for heat pumps to supply district heating. Energy, 176:156–170, 2019. doi:10.1016/j.energy.2019.03.165. ↩

  7. Peter Sorknæs. Simulation method for a pit seasonal thermal energy storage system with a heat pump in a district heating system. Energy, 152:533–538, 2018. doi:10.1016/j.energy.2018.03.152. ↩

  8. Matthew D. Jackson, Geraldine Regnier, and Iain Staffell. Aquifer thermal energy storage for low carbon heating and cooling in the United Kingdom: Current status and future prospects. Applied Energy, 376:124096, 2024. doi:10.1016/j.apenergy.2024.124096. ↩